MCP HubMCP Hub
스킬 목록으로 돌아가기

interpret-uv-vis-spectrum

pjt222
업데이트됨 Yesterday
2 조회
17
2
17
GitHub에서 보기
기타general

정보

이 스킬은 우드워드-피저 규칙을 사용하여 크로모포어를 식별하고, 전자 전이를 분류하며, 흡수 최대치를 예측하기 위해 UV-Vis 스펙트럼을 분석합니다. 또한 비어-람베르트 법칙을 통한 정량 분석을 수행합니다. 공액 시스템의 분광학 데이터 해석과 농도 결정에 활용하세요.

빠른 설치

Claude Code

추천
기본
npx skills add pjt222/agent-almanac -a claude-code
플러그인 명령대체
/plugin add https://github.com/pjt222/agent-almanac
Git 클론대체
git clone https://github.com/pjt222/agent-almanac.git ~/.claude/skills/interpret-uv-vis-spectrum

Claude Code에서 이 명령을 복사하여 붙여넣어 스킬을 설치하세요

문서

Interpret UV-Vis Spectrum

Analyze ultraviolet-visible absorption spectra to identify chromophores, classify electronic transitions, predict absorption maxima for conjugated systems, and apply the Beer-Lambert law for quantitative determination.

When to Use

  • Identifying chromophores and the extent of conjugation in an organic compound
  • Confirming the presence of aromatic rings, conjugated dienes, or enones
  • Performing quantitative analysis (determining concentration from absorbance)
  • Monitoring reaction kinetics by tracking absorbance changes over time
  • Characterizing metal-ligand complexes via d-d and charge-transfer transitions
  • Assessing solvent effects on electronic transitions (solvatochromism)

Inputs

  • Required: UV-Vis spectrum data (wavelength in nm vs. absorbance or molar absorptivity)
  • Required: Solvent used for measurement
  • Optional: Concentration and path length (for Beer-Lambert calculations)
  • Optional: Molar absorptivity (epsilon) values at lambda-max
  • Optional: Spectra in multiple solvents (for solvatochromism analysis)
  • Optional: Structural information from other spectroscopic methods

Procedure

Step 1: Verify Instrument Parameters and Spectrum Quality

Ensure the data is reliable before interpreting absorption bands:

  1. Wavelength range: Confirm the spectrum covers the relevant range. Standard UV-Vis spans 190--800 nm. Solvents impose low-wavelength cutoffs:
SolventUV Cutoff (nm)Notes
Water190Excellent UV transparency
Hexane195Non-polar, minimal solvent effects
Methanol205Protic, may cause blue shifts
Acetonitrile190Good general-purpose UV solvent
Dichloromethane230Absorbs below 230 nm
Chloroform245Absorbs below 245 nm
Acetone330Absorbs strongly, poor UV solvent
  1. Absorbance range: Reliable measurements require absorbance between 0.1 and 1.0. Below 0.1, noise dominates; above 1.0, stray light causes non-linear response. Flag any lambda-max values outside this range.
  2. Baseline and blank: Verify that a solvent blank was subtracted. Residual solvent absorption or cuvette artifacts appear as a rising baseline at short wavelengths.
  3. Slit width: Narrow slit widths give better resolution but lower signal-to-noise. If fine structure is expected (vibrational progression on electronic bands), confirm the slit width is appropriate (1--2 nm).

Got: Instrument parameters documented, solvent cutoff respected, absorbance values within the linear range, and baseline confirmed clean.

If fail: If absorbance exceeds 1.0 at lambda-max, the sample must be diluted and remeasured. If the solvent absorbs in the region of interest, recommend re-acquisition in a more transparent solvent.

Step 2: Identify Lambda-Max and Band Characteristics

Locate and characterize all absorption bands:

  1. Locate lambda-max values: Identify each absorption maximum (lambda-max) and record its wavelength (nm) and absorbance (or molar absorptivity epsilon if known).
  2. Measure band shape: Note whether each band is broad and featureless (typical of solution-phase electronic transitions) or shows vibrational fine structure (typical of rigid chromophores like polycyclic aromatics).
  3. Record shoulders: Absorption shoulders indicate overlapping transitions. Note their approximate wavelength and intensity.
  4. Classify by molar absorptivity:
epsilon (L mol-1 cm-1)Transition TypeExample
< 100Forbidden (n -> pi*)Ketone ~280 nm
100--10,000Weakly allowedAromatic 250--270 nm
10,000--100,000Fully allowed (pi -> pi*)Conjugated diene ~220 nm
> 100,000Charge transferMetal complexes, dyes

Got: All absorption maxima and shoulders tabulated with wavelength, absorbance/epsilon, and qualitative band shape.

If fail: If the spectrum shows no distinct maxima (monotonic rise), the compound may lack a chromophore in the measured range, or the concentration may be too low. Increase concentration or extend the wavelength range.

Step 3: Classify Electronic Transitions

Assign each absorption band to a specific electronic transition type:

  1. sigma -> sigma transitions* (< 200 nm): Observed only in vacuum UV. Relevant for saturated hydrocarbons and C-C/C-H bonds. Not measured in standard UV-Vis.
  2. n -> sigma transitions* (150--250 nm): Lone pair to sigma antibonding. Observed for heteroatoms (O, N, S, halogens). Saturated amines absorb near 190--200 nm; alcohols/ethers near 175--185 nm.
  3. pi -> pi transitions* (200--500 nm): Bonding pi to antibonding pi*. These are the strongest absorptions for organic compounds. Intensity and wavelength increase with extended conjugation.
  4. n -> pi transitions* (250--400 nm): Lone pair to pi antibonding. Formally forbidden (low epsilon, 10--100). Characteristic of C=O (270--280 nm for simple ketones), N=O, and C=S groups.
  5. Charge-transfer transitions: Electron transfer between donor and acceptor groups, or between metal and ligand. Typically very intense (epsilon > 10,000) and broad. Found in metal complexes and donor-acceptor organic molecules.
  6. d-d transitions (for transition metal complexes): Weak, broad bands in the visible region arising from crystal field or ligand field splitting.

Got: Each absorption band assigned to a transition type with supporting rationale (position, intensity, solvent sensitivity).

If fail: If a band cannot be assigned to a standard transition type, consider charge-transfer character or the possibility of impurity absorption. Multiple overlapping transitions may require deconvolution.

Step 4: Apply Woodward-Fieser Rules for Conjugated Systems

Predict lambda-max for conjugated dienes and enones and compare with observed values:

  1. Conjugated dienes (Woodward rules):
ComponentIncrement (nm)
Base value (heteroannular diene)214
Base value (homoannular diene)253
Each additional conjugated C=C+30
Each exocyclic C=C+5
Each alkyl substituent on C=C+5
-OAcyl substituent+0
-OR substituent+6
-SR substituent+30
-Cl, -Br substituent+5
-NR2 substituent+5
  1. Alpha-beta unsaturated carbonyls (Woodward-Fieser rules):
ComponentIncrement (nm)
Base value (alpha-beta unsat. ketone, 6-ring or acyclic)215
Base value (alpha-beta unsat. aldehyde)208
Each additional conjugated C=C+30
Each exocyclic C=C+5
Homoannular diene component+39
Alpha substituent (alkyl)+10
Beta substituent (alkyl)+12
Gamma and higher substituent (alkyl)+18
-OH (alpha)+35
-OH (beta)+30
-OAc (alpha, beta, gamma)+6
-OR (alpha)+35
-OR (beta)+30
-Cl (alpha)+15
-Cl (beta)+12
-Br (beta)+25
-NR2 (beta)+95
  1. Calculate predicted lambda-max: Sum the base value and all applicable increments.
  2. Compare with observed: Agreement within +/- 5 nm supports the proposed chromophore. Deviations > 10 nm suggest an incorrect structural assignment or strong solvent/steric effects.

Got: Predicted lambda-max calculated and compared with observed value, supporting or refuting the proposed chromophore structure.

If fail: If the predicted and observed values disagree significantly, re-examine the assumed chromophore structure. Common errors: miscounting substituents, overlooking an exocyclic double bond, or applying the wrong base value (homoannular vs. heteroannular).

Step 5: Apply Beer-Lambert Law for Quantitative Analysis

Use absorbance data for concentration determination or molar absorptivity characterization:

  1. Beer-Lambert equation: A = epsilon * b * c, where A = absorbance (dimensionless), epsilon = molar absorptivity (L mol-1 cm-1), b = path length (cm), c = concentration (mol L-1).
  2. Determine molar absorptivity: If concentration and path length are known, calculate epsilon from the measured absorbance at lambda-max.
  3. Determine concentration: If epsilon is known (from literature or a calibration curve), calculate the concentration from the measured absorbance.
  4. Check linearity: Beer-Lambert law is valid only in the linear range (A = 0.1--1.0). At higher absorbances, deviations occur due to stray light, molecular interactions, and instrumental limitations.
  5. Assess solvent effects: Compare spectra in polar vs. non-polar solvents:
    • Bathochromic (red) shift: lambda-max moves to longer wavelength. pi -> pi* transitions red-shift in more polar solvents; n -> pi* transitions red-shift in less polar solvents.
    • Hypsochromic (blue) shift: lambda-max moves to shorter wavelength. n -> pi* transitions blue-shift in more polar/protic solvents (hydrogen bonding stabilizes the lone pair ground state).
    • Hyperchromic/hypochromic effects: Increase or decrease in epsilon without wavelength change.

Got: Quantitative results calculated with appropriate significant figures, linearity verified, and solvent effects documented if spectra in multiple solvents are available.

If fail: If Beer-Lambert linearity fails, check for sample degradation, aggregation at high concentration, or fluorescence interference. Dilute the sample and remeasure to confirm.

Validation

  • Solvent cutoff respected and absorbance within the linear range (0.1--1.0)
  • All lambda-max values and shoulders tabulated with wavelength, absorbance, and epsilon
  • Each absorption band assigned to an electronic transition type
  • Woodward-Fieser calculation performed where applicable and compared with observed lambda-max
  • Beer-Lambert law applied correctly with verified linearity
  • Solvent effects characterized if multi-solvent data is available
  • Chromophore assignment consistent with molecular structure from other spectroscopic methods

Pitfalls

  • Measuring above A = 1.0: High absorbance values are unreliable due to stray light effects. Always dilute and remeasure if lambda-max absorbance exceeds 1.0.
  • Ignoring the solvent cutoff: Attempting to interpret absorptions below the solvent cutoff wavelength produces artifacts, not real sample data.
  • Confusing transition types by intensity alone: A weak band near 280 nm could be an n -> pi* transition of a carbonyl or a forbidden pi -> pi* of an aromatic. Context and solvent effects are needed to distinguish them.
  • Misapplying Woodward-Fieser rules: These empirical rules apply only to conjugated dienes and alpha-beta unsaturated carbonyls. They cannot be used for aromatic systems, isolated chromophores, or metal complexes.
  • Neglecting impurity absorption: Even small amounts of a strongly absorbing impurity can dominate the spectrum. If lambda-max does not match expectations, consider impurity contributions.
  • Assuming one band = one transition: Broad UV-Vis bands often contain multiple overlapping transitions. Band deconvolution may be necessary for accurate assignment.

Related Skills

  • interpret-nmr-spectrum -- determine molecular connectivity to support chromophore identification
  • interpret-ir-spectrum -- identify functional groups that contribute to the chromophore
  • interpret-mass-spectrum -- establish molecular formula and detect conjugation via fragmentation
  • interpret-raman-spectrum -- complementary vibrational data for symmetric chromophores
  • plan-spectroscopic-analysis -- select and sequence spectroscopic techniques before data acquisition

GitHub 저장소

pjt222/agent-almanac
경로: i18n/caveman-lite/skills/interpret-uv-vis-spectrum
0
agentsagentskillsai-assisted-developmentclaude-codeskillsteams

연관 스킬

llamaguard

기타

LlamaGuard는 폭력 및 혐오 발언 등 6가지 안전 범주에서 LLM 입력과 출력을 조정하기 위한 Meta의 70-80억 파라미터 모델입니다. 94-95% 정확도를 제공하며 vLLM, Hugging Face 또는 Amazon SageMaker를 사용해 배포할 수 있습니다. 이 기술을 사용하여 AI 애플리케이션에 콘텐츠 필터링 및 안전 가드레일을 손쉽게 통합하세요.

스킬 보기

cost-optimization

기타

이 Claude Skill은 리소스 적정화, 태깅 전략, 지출 분석을 통해 개발자들이 클라우드 비용을 최적화할 수 있도록 지원합니다. AWS, Azure, GCP에서 클라우드 비용을 절감하고 비용 거버넌스를 구현하기 위한 프레임워크를 제공합니다. 인프라 비용을 분석하거나, 리소스를 적정화하거나, 예산 제약을 충족해야 할 때 사용하세요.

스킬 보기

quantizing-models-bitsandbytes

기타

이 스킬은 bitsandbytes를 사용하여 LLM을 8비트 또는 4비트 정밀도로 양자화하며, 최소한의 정확도 손실로 50-75%의 메모리 감소를 달성합니다. 제한된 GPU 메모리에서 더 큰 모델을 실행하거나 추론을 가속화하는 데 이상적이며, INT8, NF4, FP4와 같은 형식을 지원합니다. 이 스킬은 HuggingFace Transformers와 통합되어 QLoRA 학습 및 8비트 옵티마이저를 가능하게 합니다.

스킬 보기

dispatching-parallel-agents

기타

이 Claude Skill은 3개 이상의 독립적인 문제를 동시에 조사하고 해결하기 위해 다중 에이전트를 배치합니다. 공유 상태나 의존성 없이 해결 가능한 무관련 장애 시나리오에 맞게 설계되었습니다. 핵심 기능은 병렬 문제 해결로, 각 독립 문제 영역마다 하나의 에이전트를 할당하여 효율성을 극대화합니다.

스킬 보기