interpret-chromatogram
关于
This Claude Skill interprets GC or HPLC chromatograms for developers, handling system suitability checks, peak identification, and integration. It calculates key chromatographic figures of merit and assesses peak quality to ensure reliable quantitative results. Use it for automated review and analysis of chromatographic data within a pipeline.
快速安装
Claude Code
推荐npx skills add pjt222/agent-almanac -a claude-code/plugin add https://github.com/pjt222/agent-almanacgit clone https://github.com/pjt222/agent-almanac.git ~/.claude/skills/interpret-chromatogram在 Claude Code 中复制并粘贴此命令以安装该技能
技能文档
Interpret Chromatogram
Systematic read of GC and HPLC chromatograms. Cover system suitability, peak ID, integration, chromatographic figures, peak quality. For confident qual and quant results.
When Use
- Reviewing chromatographic data before reporting
- Verify system suitability test passes before sample sequence
- Identify unknown peaks. Confirm known analytes by retention time or spectra
- Troubleshoot unexpected peaks, baseline anomalies, integration artifacts
- Training analysts on chromatogram interpretation
Inputs
Required
- Chromatogram data: Digital or printed. Time axis + detector response axis
- Reference standard data: Retention times and responses of known analytes under same method
- Method parameters: Column, mobile phase/carrier gas, temperature/gradient, detector settings
Optional
- Spectral data: UV-Vis spectra (DAD), mass spectra (MS), other spectra for peak confirmation
- Previous chromatograms: Historical data from same method for trend compare
- System suitability criteria: Acceptance limits from method or regulatory standard
- Sample prep details: Dilution factors, extraction recovery, internal standard conc
Steps
Step 1: Verify System Suitability
Confirm chromatographic system performs within spec before interpreting sample data.
| Parameter | Typical Specification | Calculation |
|---|---|---|
| Retention time RSD | <= 1.0% | RSD of tR over n >= 5 injections |
| Peak area RSD | <= 2.0% (assay), <= 5.0% (impurity) | RSD of area over n >= 5 injections |
| Tailing factor (T) | 0.8-2.0 (USP), ideally 0.9-1.2 | T = W0.05 / (2 * f) where W0.05 = width at 5% height, f = front half-width |
| Resolution (Rs) | >= 1.5 (baseline), >= 2.0 (regulated) | Rs = 2(tR2 - tR1) / (w1 + w2) |
| Theoretical plates (N) | Per column spec (e.g., >= 2000) | N = 16(tR / w)^2 or N = 5.54(tR / w0.5)^2 |
| Capacity factor (k') | 2.0-10.0 for primary analyte | k' = (tR - t0) / t0 |
- Locate system suitability injections (usually 5-6 replicates of reference standard at start of sequence)
- Calculate each parameter from table
- Compare calculated values vs method's acceptance criteria
- Any parameter fails? System not suitable. Do not proceed until issue fixed
- Document all system suitability results in batch record
Got: All system suitability parameters within spec. System fit for purpose.
If fail: Retention time RSD fails? Check temperature stability, mobile phase prep errors, column degradation. Tailing factor fails? Inspect inlet liner (GC) or column frit (HPLC). Resolution fails? Check column with dedicated test mix, replace if needed.
Step 2: Identify Peaks
- Compare each peak's retention time (tR) vs reference standard chromatogram
- Acceptable match: within +/- 2% of reference tR (or +/- 0.1 min for short runs)
- Ambiguous IDs? Use co-injection (spiking): add reference standard to sample, re-inject. Target peak should grow without broadening or shouldering
- DAD-equipped HPLC: compare UV-Vis spectrum of each peak vs spectral library
- Spectral match index >= 990 (out of 1000) for positive ID
- Check spectral purity across peak (front, apex, tail spectra should overlay)
- MS-equipped: confirm molecular ion (m/z) and key fragment ions vs reference spectra
- Flag any peak not identifiable. Report as "unknown" with retention time and relative response
Got: All target analytes identified by retention time, with spectral confirmation where available. Unknown peaks flagged with retention time and area.
If fail: Retention times shifted uniformly? Systematic change happened (column aging, temperature drift, mobile phase error). Re-inject reference standard to establish current retention times before re-evaluating.
Step 3: Integrate Peaks
- Select integration mode:
- Automatic integration with data system defaults as starting point
- Manual adjust only when automatic demonstrably misplaces baseline or peak boundaries
- Set integration parameters:
- Baseline detection sensitivity (slope sensitivity / threshold)
- Minimum peak area or height to reject noise
- Peak width parameter matching narrowest expected peak
- Verify baseline placement:
- Baseline connects start and end of each peak at true chromatographic baseline
- Overlapping peaks: use valley-to-valley or perpendicular drop per method spec
- Gradient methods: baseline may rise — use tangent skim or exponential skim for peaks on rising baseline
- Check for integration errors:
- Split peaks integrated as two when they should be one
- Shoulder peaks merged into main peak when should be separate
- Noise spikes integrated as peaks
- Baseline drawn through peak (negative peak clipping)
- Record final integration parameters and any manual adjustments with justification in audit trail
Got: All target peaks integrated with correct baseline. No artifacts. All manual adjustments documented with rationale.
If fail: Automatic integrator consistently mishandles particular peak shape? Create timed-events integration method with custom parameters for that retention window. Never manually adjust integration to get desired result — adjustments must be scientifically justified.
Step 4: Calculate Chromatographic Parameters
Calculate for all reported peaks:
- Resolution (Rs) between adjacent peaks:
- Rs = 2(tR2 - tR1) / (w1 + w2)
- Rs >= 1.5 = baseline separation. Rs >= 2.0 = margin for routine use
- Tailing factor (T) at 5% peak height:
- T = W0.05 / (2f)
- T = 1.0 = perfectly symmetric. T > 2.0 = significant tailing
- Theoretical plates (N):
- N = 16(tR / w)^2 using baseline width, or N = 5.54(tR / w0.5)^2 using half-height width
- Higher N = better column efficiency
- Capacity factor (k'):
- k' = (tR - t0) / t0 where t0 = dead time (void volume / flow rate)
- Ideal range: 2-10 for good separation with reasonable run time
- Selectivity factor (alpha) between critical pair:
- alpha = k'2 / k'1
- alpha > 1.05 needed for adequate separation
- Tabulate results for all analytes. Compare vs method specs
Got: All chromatographic parameters calculated, tabulated, compared to acceptance criteria. Critical pair resolution and plate count documented.
If fail: Calculated plates much below column spec? Column maybe degraded — test with fresh standard, compare to historical data. Parameters drift within sequence? Investigate instrument stability.
Step 5: Assess Peak Quality
- Symmetry: Peaks should be Gaussian or near-Gaussian. Significant fronting (T < 0.8) = column overload. Tailing (T > 1.5) = secondary interactions or dead volume
- Baseline separation: Quant work — critical pairs must be baseline-resolved. Valley between peaks not returning to baseline? Note percentage valley, assess impact on accuracy
- Peak width consistency: Peaks much broader than expected (vs standard) → on-column degradation, extra-column band broadening, or injection issues
- Spectral purity (DAD/MS): Purity index shows spectral inhomogeneity across peak? Co-eluting impurity likely present. Adjust method for better resolution
- Negative peaks or baseline disturbances: Negative peaks in UV = sample solvent absorbs more than mobile phase at detection wavelength — normal for solvent front, abnormal elsewhere
- Ghost peaks: Peaks in blank injection = carryover, contaminated mobile phase, or column bleed. Identify source before reporting sample results
- Summarize overall chromatographic quality. Note any limitations on reported results
Got: Peak quality assessed for all target analytes. Any anomalies (tailing, co-elution, ghost peaks) documented with potential impact on data quality.
If fail: Significant quality issues found (co-elution confirmed by spectral impurity, ghost peaks at analyte retention times)? Data may not be reportable. Flag results, investigate root cause, re-run after corrective action.
Checks
- System suitability parameters calculated and within spec
- All target analytes identified by retention time (+/- spectral confirmation)
- Unknown peaks flagged with retention time and area
- Integration done with correct baseline. Manual adjustments documented
- Resolution, tailing, plates, capacity factor calculated for all peaks
- Peak quality assessed — no unresolved co-elutions affecting quantitation
- Ghost peaks and carryover evaluated via blank injection
- Results tabulated and compared vs method acceptance criteria
Pitfalls
- Accept automatic integration without review: Data systems misplace baselines, especially for shoulders, small peaks near large ones, gradient baselines. Every chromatogram needs visual review.
- Confuse retention time shift with new peak: Uniform shifts (all peaks move together) = systematic change, not new compounds. Re-inject standard to recalibrate before making ID calls.
- Report peaks below noise: Peaks with S/N below 3 (detection) or 10 (quantitation) should not be identified or quantitated. Calculate S/N explicitly for trace-level peaks.
- Ignore solvent front: Void volume peak not an analyte. Ensure t0 correctly identified and excluded from analyte reporting.
- Manual integration to hit target result: Adjusting integration to make result pass spec = data falsification. All integration changes must be scientifically justified, audit-trailed.
- Neglect spectral purity checks: Clean-looking peak can hide co-eluting impurity. Always check peak purity when DAD or MS data available.
See Also
develop-gc-method— method dev for GC technique making chromatogramdevelop-hplc-method— method dev for HPLC technique making chromatogramtroubleshoot-separation— diagnose problems found during chromatogram interpretationvalidate-analytical-method— formal validation of method generating chromatographic datainterpret-mass-spectrum— detailed interpretation of MS data for GC-MS and LC-MS peak confirmation
GitHub 仓库
相关推荐技能
executing-plans
设计该Skill用于当开发者提供完整实施计划时,以受控批次方式执行代码实现。它会先审阅计划并提出疑问,然后分批次执行任务(默认每批3个任务),并在批次间暂停等待审查。关键特性包括分批次执行、内置检查点和架构师审查机制,确保复杂系统实现的可控性。
requesting-code-review
设计该Skill可在完成任务、实现主要功能或合并代码前自动调度代码审查子代理,确保实现符合需求和计划。它支持通过指定git SHA范围进行精准的代码变更审查,帮助开发者在关键节点及时发现潜在问题。核心原则是"早审查、勤审查",适用于开发流程的各个关键阶段。
connect-mcp-server
设计这个Skill指导开发者如何将MCP服务器连接到Claude Code,支持HTTP、stdio和SSE三种传输协议。它涵盖了从安装配置到认证安全的完整流程,适用于集成GitHub、Notion、数据库等外部服务。当开发者需要添加集成、配置外部工具或提及MCP相关功能时,这个Skill能提供实用的操作指南。
web-cli-teleport
设计该Skill帮助开发者根据任务特性选择Claude Code的Web或CLI界面,并指导如何在两种环境间无缝迁移会话。它能分析任务复杂度、迭代需求等要素,推荐最优工作界面和工作流。关键特性包括会话状态管理、环境切换指导和上下文优化建议。
