返回技能列表

solve-electromagnetic-induction

pjt222
更新于 Yesterday
4 次查看
17
2
17
在 GitHub 上查看
设计design

关于

This skill solves electromagnetic induction problems by applying Faraday's law, Lenz's law, and circuit analysis for RL transients. It handles induced EMF from changing magnetic fields or moving conductors, determines current direction, and calculates inductance with magnetic energy storage. Use it when analyzing induction in loops/coils, motional EMF scenarios, or RL circuit switching behavior.

快速安装

Claude Code

推荐
主要方式
npx skills add pjt222/agent-almanac -a claude-code
插件命令备选方式
/plugin add https://github.com/pjt222/agent-almanac
Git 克隆备选方式
git clone https://github.com/pjt222/agent-almanac.git ~/.claude/skills/solve-electromagnetic-induction

在 Claude Code 中复制并粘贴此命令以安装该技能

技能文档

Solve EM Induction

ID flux source → compute flux through surface → Faraday → EMF → Lenz → current direction → solve circuit eqns (RL transients + mag field energy).

Use When

  • Induced EMF in loop/coil from time-varying B
  • Motional EMF from conductor moving in static B
  • Current direction via Lenz
  • Mutual M (coupled coils) | self-L (single coil)
  • RL transients (energize, de-energize, switch)
  • Mag field energy | inductor energy

In

  • Required: Source of changing flux (time-varying B, moving conductor, changing area)
  • Required: Geometry of circuit/loop
  • Required: Phys params (B mag, vel, R, L, geometry)
  • Optional: Other circuit elements (R, additional L, sources)
  • Optional: Initial conditions (I_0, U_0)
  • Optional: Time interval

Do

Step 1: ID Flux Source

Classify mechanism producing time-varying flux:

  1. Changing B: B(t) varies. Loop static. (AC magnet, approaching magnet, current ramp in nearby coil)
  2. Changing area: A(t) varies. B may be static. (expanding/contracting loop, rotating coil in static field)
  3. Motional EMF: Straight conductor through static B. Flux change = conductor sweeping area.
  4. Combined: Both field + geometry change. Separate contributions for clarity.

Per mechanism, ID surface S bounded by loop C:

## Flux Change Classification
- **Mechanism**: [changing B / changing area / motional / combined]
- **Surface S**: [description of the surface bounded by the loop]
- **Time dependence**: [which quantities vary: B(t), A(t), v(t), theta(t)]
- **Relevant parameters**: [B magnitude, loop dimensions, velocity, angular frequency]

Got: Clear ID of why flux changes, surface to integrate, which quantities carry time dep.

If err: Ambiguous (deforming loop in non-uniform field) → decompose: field change at fixed geom + geom change in instantaneous field. Always valid.

Step 2: Calculate Magnetic Flux

Compute Phi_B = ∫ B·dA over S:

  1. Uniform field, flat loop: Phi_B = B·A·cos(theta), theta = angle B vs n_hat. Most common.

  2. Non-uniform: Parameterize S, eval integral:

    • Coords aligned w/ surface (polar for circular loop)
    • Express B(r) at each point
    • Dot product B·dA = B·n_hat dA
    • Integrate
  3. Coupled coils (mutual M): Coil 2 linked to 1:

    • B_1 (from coil 1) at coil 2 location
    • Integrate B_1 over each turn of coil 2
    • × N_2 → flux linkage Lambda_21 = N_2·Phi_21
    • M = Lambda_21 / I_1
  4. Self-L: Single coil w/ I:

    • B inside from own current
    • Integrate over one turn × N
    • L = N·Phi/I = Lambda/I
    • Known: solenoid L = mu_0·n²·A·l; toroid L = mu_0·N²·A/(2π·R)
  5. Time dep: Express Phi_B(t) via time-varying quantities from Step 1.

## Flux Calculation
- **Flux expression**: Phi_B(t) = [formula]
- **Evaluation**: [analytic / numeric]
- **Flux linkage** (if multi-turn): Lambda = N * Phi_B = [formula]
- **Inductance** (if applicable): L = [value with units] or M = [value with units]

Got: Explicit Phi_B(t), correct units (Wb = T·m²), inductance in H.

If err: Integral can't be analytical (non-uniform B over non-trivial S) → numerical quadrature. Mutual M for complex geom → Neumann formula: M = (mu_0/4π)·∮∮(dl_1·dl_2)/|r_1 - r_2|.

Step 3: Faraday → EMF

Compute induced EMF from time deriv of flux:

  1. Faraday: EMF = -dLambda/dt = -N·dPhi_B/dt. Negative sign = Lenz.

  2. Differentiate Phi_B(t):

    • B = B(t), A + theta const → EMF = -N·A·cos(theta)·dB/dt
    • theta = omega·t (rotating in static B) → EMF = N·B·A·omega·sin(omega·t)
    • Area changes (sliding rail) → EMF = -B·l·v (motional EMF)
    • General → Leibniz integral rule
  3. Motional EMF (alt): Conductor length l, vel v in B:

    • Lorentz on charges: F = q(v × B)
    • EMF = ∫(v × B)·dl along conductor
    • Equiv to Faraday, more intuitive for moving conductors
  4. Sign + magnitude check: Lab setups: mV-V. Power gen: V-kV.

## Induced EMF
- **EMF expression**: EMF(t) = [formula]
- **Peak EMF** (if AC): EMF_0 = [value with units]
- **RMS EMF** (if AC): EMF_rms = EMF_0 / sqrt(2) = [value]
- **Derivation method**: [Faraday's law / motional EMF / Leibniz rule]

Got: Explicit EMF(t), correct units (V), reasonable magnitude.

If err: Wrong units → trace flux calc; missing area factor | mixing CGS/SI. Wrong sign → re-examine surface normal vs loop direction (right-hand rule).

Step 4: Lenz → Current Direction

ID induced current direction + phys consequences:

  1. Lenz: Induced current opposes the flux change that produced it. = Energy conservation.

  2. Apply:

    • Flux ↑ → induced current → B opposes ↑ (opposite external B through loop)
    • Flux ↓ → induced current → B supports ↓ (same direction as external B)
    • Right-hand rule → B direction → current direction
  3. Force consequences: Induced current in external B → force:

    • Eddy current braking: opposes relative motion (always decel)
    • Mag levitation: repulsive supports weight (right geom)
    • Lenz at mechanical level
  4. Qual verify: Effects always resist change. Falling magnet through conductor tube falls slower than free fall. Generator needs mech work in → elec energy.

## Current Direction
- **Flux change**: [increasing / decreasing]
- **Induced B direction**: [opposing increase / supporting decrease]
- **Current direction**: [CW / CCW as viewed from specified direction]
- **Mechanical consequence**: [braking force / levitation / energy transfer]

Got: Clear current direction consistent w/ Lenz, phys consequence ID'd.

If err: Current amplifies flux change → surface normal | RH rule reversed. Re-examine loop convention. Current reinforcing change → violates energy conservation.

Step 5: Solve Circuit Eqn

Formulate + solve circuit eqn w/ inductance:

  1. RL formation: Induced EMF drives I through R + L, KVL gives:

    • Energize (switch → DC V_0): V_0 = L·dI/dt + R·I
    • De-energize (source removed, loop closed): 0 = L·dI/dt + R·I
    • General (time-varying EMF): EMF(t) = L·dI/dt + R·I
  2. Solve 1st-order ODE:

    • Energize: I(t) = (V_0/R)·[1 - exp(-t/tau)], tau = L/R
    • De-energize: I(t) = I_0·exp(-t/tau)
    • AC EMF = EMF_0·sin(omega·t) → phasor methods | particular + homogeneous
    • Transient: ~63% final after 1·tau, ~95% after 3·tau, ~99.3% after 5·tau
  3. Energy:

    • Inductor: U_L = (1/2)·L·I²
    • Mag field per vol: u_B = B²/(2·mu_0) vacuum, (1/2)·B·H mag materials
    • R dissipation: P_R = I²·R
    • Conservation: rate energy in = rate stored + rate dissipated
  4. Mutual M coupling: Two coupled coils:

    • V_1 = L_1·dI_1/dt + M·dI_2/dt + R_1·I_1
    • V_2 = M·dI_1/dt + L_2·dI_2/dt + R_2·I_2
    • Coupling k = M/sqrt(L_1·L_2), 0 ≤ k ≤ 1
    • Solve coupled ODEs (matrix exp | Laplace)
  5. Steady-state vs transient: AC drive → decompose transient (decaying exp) + steady-state (sinusoidal at drive freq). Report Z_L = j·omega·L + phase angle.

## Circuit Solution
- **Circuit type**: [RL energizing / de-energizing / AC driven / coupled coils]
- **Time constant**: tau = L/R = [value with units]
- **Current solution**: I(t) = [expression]
- **Energy stored**: U_L = [value at specified time]
- **Energy dissipated**: [total or rate]
- **Steady-state impedance** (if AC): Z_L = [value]

Got: Complete time-domain I solution, correct exp time constants, energy balance verified, reasonable magnitudes.

If err: Current grows unbounded → sign err in ODE (L term must oppose dI). Tau unreasonable → recheck L (Step 2) + R. Lab RL tau: μs to s.

Check

  • Source of flux change clearly ID'd
  • Flux integral over correct S w/ proper orientation
  • Flux units Wb = T·m²
  • L (self/mutual) units H, reasonable mag
  • EMF units V, reasonable mag
  • EMF sign consistent w/ Lenz
  • Current dir via Lenz + RH rule
  • RL ODE correct setup, proper signs
  • tau = L/R units s, reasonable mag
  • Energy balance: in = stored + dissipated
  • Limits checked (t→0 init, t→∞ steady)

Traps

  • Wrong sign Faraday: EMF = -dLambda/dt, NOT +. Negative = Lenz + energy conservation. Omit → current amplifies flux change → violates thermo.
  • Flux vs flux linkage: Single-turn: Phi_B = Lambda. N-turn: Lambda = N·Phi_B. L = Lambda/I, NOT Phi_B/I. Missing N factor → L is N× too small.
  • Surface normal inconsistency: n_hat must be RH-rule related to loop circulation. Independent → sign errs in flux + EMF.
  • Ignore back-EMF (RL): Current changes in L → back-EMF opposes change. Omit from KVL → algebraic not differential → miss transient entirely.
  • Instant current change: Current through ideal L can't change instant (needs ∞ V). Initial conds for RL transients must satisfy continuity across switches.
  • Eddy currents bulk conductors: Faraday applies to ANY closed path in conductor, not just wire loops. Time-varying fields in bulk → distributed eddy currents → heating + shielding. Critical in transformer cores → minimize w/ lamination.

  • analyze-magnetic-field — compute B from current distributions = flux source
  • formulate-maxwell-equations — generalize induction → full Maxwell + displacement current
  • design-electromagnetic-device — apply to motors, generators, transformers
  • derive-theoretical-result — derive analytic L, EMF, transient solutions from first principles

GitHub 仓库

pjt222/agent-almanac
路径: i18n/caveman-ultra/skills/solve-electromagnetic-induction
0
agentsagentskillsai-assisted-developmentclaude-codeskillsteams

相关推荐技能

executing-plans

设计

该Skill用于当开发者提供完整实施计划时,以受控批次方式执行代码实现。它会先审阅计划并提出疑问,然后分批次执行任务(默认每批3个任务),并在批次间暂停等待审查。关键特性包括分批次执行、内置检查点和架构师审查机制,确保复杂系统实现的可控性。

查看技能

requesting-code-review

设计

该Skill可在完成任务、实现主要功能或合并代码前自动调度代码审查子代理,确保实现符合需求和计划。它支持通过指定git SHA范围进行精准的代码变更审查,帮助开发者在关键节点及时发现潜在问题。核心原则是"早审查、勤审查",适用于开发流程的各个关键阶段。

查看技能

connect-mcp-server

设计

这个Skill指导开发者如何将MCP服务器连接到Claude Code,支持HTTP、stdio和SSE三种传输协议。它涵盖了从安装配置到认证安全的完整流程,适用于集成GitHub、Notion、数据库等外部服务。当开发者需要添加集成、配置外部工具或提及MCP相关功能时,这个Skill能提供实用的操作指南。

查看技能

web-cli-teleport

设计

该Skill帮助开发者根据任务特性选择Claude Code的Web或CLI界面,并指导如何在两种环境间无缝迁移会话。它能分析任务复杂度、迭代需求等要素,推荐最优工作界面和工作流。关键特性包括会话状态管理、环境切换指导和上下文优化建议。

查看技能